Add to Cart
1:Open loop vector control, VIF control
2:Overload capacity is 60s for 150% of rate current,3s for 180% of rate current.
3: High performance; environmental adaptationSimple structure; Compact size; Easy installEconomic vector control inverter,high torque output, motor runs smoothly when heavy loading.
4:Instantaneous stop doesn't stop,reduce the rate of frequent fault alarm.
5:Protection function: Output phase loss protection,Over-current protection, Over-voltage protection,Overload protection, Over-heat protection etc.
6:The terminal design is simple to install, specially designed for air compressor; Equipped with ZONCN self-developed HMI controller, the effect is better.
Item | NZ200T |
Control Mode | Sensorless flux vector control(SFVC) Voltage/Frequency (V/F) Control |
Maximum frequency | Vector control:0-320Hz V/F control:0-3200Hz |
Carrier frequency | 1kHz~16kHz The carrier frequency is automatically adjusted based on the load features. |
Input frequency resolution | Digital setting:0.01Hz Analog setting: Maximum frequency 0.025% |
Start torque | G: Type:0.5Hz/150%(SVC) P: Type:0.5Hz/100% |
Speed range | 1:100(SVC) |
Speed stability accuracy | ±0.5%(SVC) |
Overload capacity | G Type:60s for 150% of the rated current, 3s for 180% of the rated current. P Type:60s for 120% of the rated current, 3s for 150% of the rated current. |
Torque boost | Auto-boost ; Customized boost:0.1%~30.0% |
VF curve | Straight-line VF curve; Multi-point VF curve; N-power VF curve(1.2-power,1.4-power,1.6-power,1.8-power, 2-power) |
VF separation | 2 types: complete separation;half separation |
Ramp Mode | Straight-line ramp;S-curve ramp;Four groups of acceleration/deceleration time:0~6500.0s |
Simple PLC, Multiple preset speeds | It implements up to 16 speeds via the simple PLC function or combination of terminal states |
Auto voltage regulation(AVR) | It can keep constant output voltage automatically when the mains voltage changes |
Rapid current limit | It helps to avoid frequent over current faults of the AC drive. |
Torque limit and control | It can limit the torque automatically and prevent frequent over-current tripping during the running process. |
Onboard PID | It realizes process-controlled closed loop control system easily |
Rapid current limit | It helps to avoid frequent over current faults of the AC drive. |
JOG control | JOG frequency range: 0.00–50.00 Hz JOG acceleration/deceleration time: 0.0–6500.0s |
DC braking | DC braking frequency:0.00Hz to maximum frequency Braking time:0.0-100.0s Braking action current value:0.0%-100.0% |
Instantaneous blackout doesn’t stop | The load feedback energy compensates the voltage reduction so that the AC drive can continue to run for a short time. |
Timing control | Timing range:0.0Min~6500.0Min |
Communication | RS485 |
Run instruction channel | Keyboard given, control terminal given, serial communication port given. It can be switched in a variety of ways. |
Frequency source | 10 kinds: digital given, analog voltage given, analog current given, pulse given, serial port given. It can be switched in a variety of ways. |
Auxiliary frequency source | 10 auxiliary frequency sources. It can flexibly realize auxiliary frequency fine-tuning and frequency synthesis. |
Input terminals | 6 digital input terminals, one of which supports up to 100 kHz high-speed pulse input (S3 optional). 2 analog input terminal, one of which only supports 0-10v voltage input(FIV) and the other supports 0-10 voltage input or 4-20 mA current input(FIC). |
Output terminals | 1 digital output terminal(MO1) 1 relay output terminal(RA,RB,RC) 1 analog output terminal :that supports 0-20 mA current output or 0-10v voltage output(FOV) |
Remark | X terminal is NPN type by default. If PNP type is required, contact customer service for customization. |
LED display | Not removable. More than 45kw is acceptable. |
Keystroke locking and function selection | Realize partial or full lock of keys, and define the scope of action of some keys to prevent false touch |
Multiple protection modes | Motor short-circuit detection at power-on, output phase loss protection, over-current protection, over-voltage protection, under voltage protection, overheat protection and overload protection. |
Type | Input voltage | Rated output power(KW) | Rated input current(A) | Rated output current (A) | Motor power ( KW) |
NZ200T-0R4G-2 |
AC 220V
| 0.4 | 5.4 | 2.5 | 0.4 |
NZ200T-0R75G-2 | 0.75 | 7.2 | 5.0 | 0.75 | |
NZ200T-1R5G-2 | 1.5 | 10.0 | 7.0 | 1.5 | |
NZ200T-2R2G-2 | 2.2 | 16 | 11 | 2.2 | |
NZ200T-3R7G-2 | 3.7 | 24 | 16.5 | 3.7 | |
NZ200T-0R4G-4 |
AC 380V
| 0.4 | 3.4 | 1.2 | 0.4 |
NZ200T-0R75G-4 | 0.75 | 3.8 | 2.5 | 0.75 | |
NZ200T-1R5G-4 | 1.5 | 5.0 | 3.7 | 1.5 | |
NZ200T-2R2G-4 | 2.2 | 5.8 | 5.0 | 2.2 | |
NZ200T-3R7G/5R5P-4 | 3.7/5.5 | 10/15 | 9/13 | 3.7/5.5 | |
NZ200T-5R5G/7R5P-4 | 5.5/7.5 | 15/20 | 13/27 | 5.5/7.5 | |
NZ200T-7R5G/11P-4 | 7.5/11 | 20/26 | 17/25 | 7.5/11 | |
NZ200T-11G/15P-4 | 11/15 | 26/35 | 25/32 | 11/15 | |
NZ200T-15G/18.5P-4 | 15/18.5 | 35/38 | 32/37 | 15/18.5 | |
NZ200T-18.5G/22P-4 | 18.5/22 | 38/46 | 37/45 | 18.5/22 | |
NZ200T-22G/30P-4 | 22/30 | 46/62 | 45/60 | 22/30 | |
NZ200T-30G/37P-4 | 30/37 | 62/76 | 60/75 | 30/37 | |
NZ200T-37G/45P-4 | 37/45 | 76/90 | 75/90 | 37/45 | |
NZ200T-45G/55P-4 | 45/55 | 90/105 | 90/110 | 45/55 | |
NZ200T-55G-4 | 55 | 105 | 110 | 55 | |
NZ200T-75P-4 | 75 | 140 | 150 | 75 | |
NZ200T-75G/90P-4 | 75/90 | 140/160 | 150/176 | 75/90 | |
NZ200T-90G/110P-4 | 90/110 | 160/210 | 176/210 | 90/110 | |
NZ200T-110G/132P-4 | 110/132 | 210/240 | 210/253 | 110/132 | |
NZ200T-132G/160P-4 | 132/160 | 240/290 | 253/300 | 132/160 | |
NZ200T-160G/185P-4 | 160/185 | 290/330 | 300/340 | 160/185 | |
NZ200T-185G/200P-4 | 185/200 | 330/370 | 340/380 | 185/200 | |
NZ200T-200G/220P-4 | 200/220 | 370/410 | 380/420 | 200/220 | |
NZ200T-220G/250P-4 | 220/250 | 410/460 | 420/470 | 220/250 | |
NZ200T-250G/280P-4 | 250/280 | 460/500 | 470/520 | 250/280 | |
NZ200T-280G/315P-4 | 280/315 | 500/580 | 520/600 | 280/315 | |
NZ200T-315G/350P-4 | 315/350 | 580/620 | 600/640 | 315/350 | |
NZ200T-350G/400P-4 | 350/400 | 620/670 | 640/690 | 350/400 | |
NZ200T-400G/450P-4 | 400/450 | 670/790 | 690/790 | 400/450 |