ZONCN Z8000 Series High Performance Close Loop Vector Control
Product Features
Product description
Item | Z8000 | |
Standard Function | Control mode | Senseless flux vector control(SFVC) ; Closed-loop vector control; V/F control |
Maximum frequency | Vector control: 0-320Hz ; V/F control: 0-3200Hz | |
Carrier frequency | 1-16kHz ; The carrier frequency is automatically adjusted based on the load features | |
Input frequency solution | Digital setting: 0.01Hz ; Analog setting: 0.025% of maximum frequency | |
Startup torque | G type: 0.5Hz/150%(SFVC) ; 0 Hz/180% (CLVC) P type: 0.5Hz/100% | |
Speed range | 1:100 (SFVC); 1:1000 (CLVC) | |
Speed stability accuracy | ±0.2% (SFVC); ±0.2% (CLVC) | |
Overload capacity | G type: 60s for 150% of the rated current, 3s for 180% of the rated current. P type: 60s for 120% of the rated current, 3s for 150% of the rated current. | |
Torque boost | Auto boost ; Customized boost 0.1%-30.0% | |
V/F curve | Line V/F curve; Multi-point V/F curve; N-power V/F curve(1.2-power, 1.4-power, 1.6-power, 1.8-power, square) | |
V/F separation | Two types: complete separation; half separation | |
Ramp mode | Straight-line ramp ; S-curve ramp ; Four groups of acceleration/deceleration time with the range of 0.0-6500.0s | |
DC braking | DC braking frequency : 0.0Hz to maximum frequency Braking time: 0.0~100.0s Braking action current value: 0.0%~100.0% | |
JOG control | JOG frequency range: 0.00~50.00Hz JOG acceleration/deceleration time: 0.0~6500.0s | |
Onboard multiple preset speeds | It implements up to 16 speeds via the simple PLC function or combination of terminal states. | |
Onboard PID | It realizes process-controlled closed loop control system easily | |
Auto voltage regulation(AVR) | It can keep constant output voltage automatically when the mains voltage changes. | |
Auto voltage/ Over current stall control | The current and voltage are limited automatically during the running process so as to avoid frequent tripping due to overvoltage/over current | |
Rapid current limit | It helps to avoid frequent over current faults of the AC drive | |
Torque limit and control | It can limit the torque automatically and prevent frequent over current tripping during the running process. Toque control can be implemented in the CLVC mode. |
Model | Rated Output Power(kW) | Rated Input Current(A) | Rated Output Current(A) | Motor Equipped(kW) |
Input Voltage:1PH or 3PH AC 220V±15% | ||||
Z8200-0R4G | 0.4 | 5.4 | 2.5 | 0.4 |
Z8200-0R75G | 0.75 | 7.2 | 5 | 0.75 |
Z8200-1R5G | 1.5 | 10 | 7 | 1.5 |
Z8200-2R2G | 2.2 | 16 | 11 | 2.2 |
Z8200-3R7G | 3.7 | 23 | 16.5 | 3.7 |
Input Voltage:3PH AC 380V±15% | ||||
Z8400-0R75G | 0.75 | 3.8 | 2.5 | 0.75 |
Z8400-1R5G | 1.5 | 5 | 3.7 | 1.5 |
Z8400-2R2G | 2.2 | 5.8 | 5 | 2.2 |
Z8400-3R7G/5R5P | 3.7/5.5 | 10/15.0 | 9/13 | 3.7/5.5 |
Z8400-5R5G/7R5P | 5.5 | 15 | 13 | 5.5 |
Z8400-7R5G/11P | 7.5/11 | 20/26 | 17/25 | 7.5/11 |
Z8400-11G/15P | 11/15 | 26/35 | 25/32 | 11/15 |
Z8400-15G/18.5P | 15/18.5 | 35/38 | 32/37 | 15/18.5 |
Z8400-18.5G/22P | 18.5/22 | 38/46 | 37/45 | 18.5/22 |
Z8400-22G/30P | 22/30 | 46/62 | 45/60 | 22/30 |
Z8400-30G/37P | 30/37 | 62/76 | 60/75 | 30/37 |
Z8400-37G/45P | 37/45 | 76/90 | 75/90 | 37/45 |
Z8400-45G/55P | 45/55 | 90/105 | 90/110 | 45/55 |
Z8400-55G | 55 | 105 | 110 | 55 |
Z8400-75G/90P | 75/90 | 140/160 | 150/176 | 75/90 |
Z8400-90G/110P | 90/110 | 160/210 | 176/210 | 90/110 |
Z8400-110G/132P | 110/132 | 210/240 | 210/253 | 110/132 |
Z8400-132G/160P | 132/160 | 240/290 | 253/300 | 132/160 |
Z8400-160G/185P | 160/185 | 290/330 | 300/340 | 160/185 |
Z8400-185G/200P | 185/200 | 330/370 | 340/380 | 185/200 |
Z8400-200G/220P | 200/220 | 370/410 | 380/420 | 200/220 |
… | ||||
Z8400-1000G | 1000 | 1800 | 1720 | 1000 |