Add to Cart
Frequency Converter 1.5kw 2hp VFD 220v 3phase Variadores De Frecencia With Rs485
Item | Z2000 Inverter | |
Standard Function | Control mode | Senseless flux vector control(SFVC) ; Voltage/Frequency (V/F) control |
Maximum frequency | Vector control: 0-320Hz ; V/F control: 0-3200Hz | |
Carrier frequency | 1-16kHz ; The carrier frequency is automatically adjusted based on the load features | |
Input frequency solution | Digital setting: 0.01Hz ; Analog setting: maximum frequency x 0.025% | |
Startup torque | G type: 0.5Hz/150%(SFVC) ; P type: 0.5Hz/100% | |
Speed range | 1:100 | |
Speed stability accuracy | ±0.5% | |
Overload capacity | G type: 60s for 150% of the rated current, 3s for 180% of the rated current. P type: 60s for 120% of the rated current, 3s for 150% of the rated current. | |
Torque boost | Auto boost ; Customized boost 0.1%-30.0% | |
V/F curve | Line V/F curve; Multi-point V/F curve; N-power V/F curve | |
V/F separation | Two types: complete separation; half separation | |
Ramp mode | Straight-line ramp ; S-curve ramp ; Four groups of acceleration/deceleration time with the range of 0.0-6500.0s | |
DC braking | DC braking frequency : 0.0Hz to maximum frequency Braking time: 0.0~100.0s Braking action current value: 0.0%~100.0% | |
JOG control | JOG frequency range: 0.00~50.00Hz JOG acceleration/deceleration time: 0.0~6500.0s | |
Onboard multiple preset speeds | It implements up to 16 speeds via the simple PLC function or combination of X terminal states. | |
Onboard PID | It realizes process-controlled closed loop control system easily | |
Auto voltage regulation(AVR) | It can keep constant output voltage automatically when the mains voltage changes. | |
Auto voltage/ Over current stall control | The current and voltage are limited automatically during the running process so as to avoid frequent tripping due to overvoltage/over current | |
Rapid current limit | It helps to avoid frequent over current faults of the AC drive | |
Torque limit and control | It can keep constant output voltage automatically when the mains voltage changes |
Inverter Model | Rated Output Power(kW) | Rated Input Current(A) | Rated Output Current(A) | Motor Equipped(kW) |
Input Voltage:1PH or 3PH AC 220V±15% | ||||
Z2200-0R4G | 0.4 | 5.4 | 2.5 | 0.4 |
Z2200-0R75G | 0.75 | 7.2 | 5 | 0.75 |
Z2200-1R5G | 1.5 | 10 | 7 | 1.5 |
Z2200-2R2G | 2.2 | 16 | 11 | 2.2 |
Z2200-3R7G | 3.7 | 23 | 16.5 | 3.7 |
Z2200-5R5G | 5.5 | 21 | 25 | 5.5 |
Z2200-7R5G | 7.5 | 31 | 32 | 7.5 |
Input Voltage:3PH AC 380V±15% | ||||
Z2400-0R75G | 0.75 | 3.8 | 2.5 | 0.75 |
Z2400-1R5G | 1.5 | 5 | 3.7 | 1.5 |
Z2400-2R2G | 2.2 | 5.8 | 5 | 2.2 |
Z2400-3R7G/5R5P | 3.7/5.5 | 10/15.0 | 9/13 | 3.7/5.5 |
Z2400-5R5G | 5.5 | 15 | 13 | 5.5 |
Z2400-7R5G/11P | 7.5/11 | 20/26 | 17/25 | 7.5/11 |
Z2400-11G/15P | 11/15 | 26/35 | 25/32 | 11/15 |
Z2400-15G/18.5P | 15/18.5 | 35/38 | 32/37 | 15/18.5 |
Z2400-18.5G/22P | 18.5/22 | 38/46 | 37/45 | 18.5/22 |
Z2400-22G/30P | 22/30 | 46/62 | 45/60 | 22/30 |
Z2400-30G/37P | 30/37 | 62/76 | 60/75 | 30/37 |
Z2400-37G/45P | 37/45 | 76/90 | 75/90 | 37/45 |
Z2400-45G/55P | 45/55 | 90/105 | 90/110 | 45/55 |
Z2400-55G | 55 | 105 | 110 | 55 |
Z2400-75G/90P | 75/90 | 140/160 | 150/176 | 75/90 |
Z2400-90G/110P | 90/110 | 160/210 | 176/210 | 90/110 |
Z2400-110G/132P | 110/132 | 210/240 | 210/253 | 110/132 |
Z2400-132G/160P | 132/160 | 240/290 | 253/300 | 132/160 |
Z2400-160G/185P | 160/185 | 290/330 | 300/340 | 160/185 |
Z2400-185G/200P | 185/200 | 330/370 | 340/380 | 185/200 |
Z2400-200G/220P | 200/220 | 370/410 | 380/420 | 200/220 |
… |
*Note: If you have any special requirements for VFD inverter, pls feel free to contact us directly, we can customize for you.
1. Do you support for any techinical questions for your inverter?
A: Sure, if you have any quesitions for our inverter, pls feel free to contact us.
2. Does your inverter support other communications?
A. We have different series of inverters which support RS485, profinet, profibus, EtherCAT, Canopen, Modbus TCP, etc.